Roots blowers for process gas conveying can move or boost a gas stream when its composition, flow and pressure duty fit the selected machine. Chemical plants use process gas in reactors, scrubbers, heat exchangers, filters, recovery systems and distribution headers. Each component adds resistance, while gas composition affects density, temperature rise, sealing and material compatibility.
A rotary-lobe blower may suit a defined low- or moderate-pressure duty that requires substantial volumetric flow. It is not automatically suitable for every process gas or pressure ratio. Its performance must be checked against actual inlet conditions and the complete process route.
Define the Process-Gas Duty
Process-gas conveying moves a gas through equipment or piping to support a process step. Boosting raises its pressure enough to overcome downstream resistance or meet the inlet requirement of the destination. Depending on the plant, a blower may transfer gas between process vessels, circulate it through a treatment loop, or feed a gas stream to an adsorption or recovery unit.
Potential pressure losses include piping and fittings, control valves, filters, scrubbers, heat exchangers, condensers, reactors and the destination equipment. A clean filter’s resistance may differ from its loaded resistance. A valve’s operating position or a change in destination pressure can also shift the duty.
Specify the gas at the blower inlet, not only by its process name. The analysis should cover normal composition and credible changes during start-up, shutdown, purging, cleaning or process upset. Include trace compounds where they may affect corrosion, deposits, seals, temperature or downstream product quality. Water vapour, condensable hydrocarbons, solvent vapours and entrained droplets can make a nominally gaseous stream a different mechanical duty.
A standard air blower rating does not establish suitability for hydrogen, hydrocarbons, hydrogen sulphide, carbon monoxide or solvent vapours. Gas properties and hazards vary. The supplier needs the composition range, operating temperature, moisture or dew point, potential liquid carryover, and any particulate contamination before assessing materials and machine configuration.
How a Roots Blower Transfers Process Gas
Two synchronized lobed rotors turn without normally contacting each other or the casing. They carry gas from the inlet to the discharge in trapped volumes. Timing gears maintain the rotor relationship; bearings and gears are outside the compression chamber in conventional designs.
The gas is not substantially compressed inside the rotor chamber. External compression occurs when the transferred gas reaches the discharge port and encounters the higher pressure in the connected system. This creates pressure equalization at the discharge, so the blower and process equipment must be evaluated together.
The blower’s theoretical displacement per revolution is nearly fixed, but actual delivery is not independent of operating conditions. Internal slip allows some discharge gas to pass back toward the inlet. Slip depends on clearances, differential pressure, speed and gas properties, among other factors. Temperature and density also influence the actual inlet volume and absorbed power. Air-based performance cannot be transferred to another gas without an appropriate calculation.
Convert Flow and Calculate Pressure
A flow value in normal or standard cubic metres per hour is not the volume entering the blower at site conditions. Convert it to the actual inlet volume flow using the stated reference pressure and temperature. For a gas composition that remains the same between reference and inlet conditions:
Volumetric Flow Correction (Inlet Conditions)
Use absolute pressure and absolute temperature in kelvin. State the reference conditions and whether the reported flow is on a dry or wet basis. If the composition changes, update the density and compressibility properties for that case.
Gas density can be estimated from:
Gas Density
Here, M is the mixture’s molar mass, calculated from component molar masses and mole fractions. Use consistent units; for example, pascals for pressure, kilograms per mole for molar mass, and joules per mole-kelvin for the universal gas constant.
Calculate differential pressure at the blower flanges. First determine pressure at the suction flange from the source boundary pressure and upstream losses. Then determine discharge-flange pressure from the destination requirement and downstream losses:
System Pressures & Blower Pressure Difference
Use a consistent pressure reference for this balance. For pressure ratio, use absolute pressures:
Absolute Pressure Ratio
Gauge pressure must not be used in this ratio. This distinction is especially relevant when the blower draws from a source below atmospheric pressure.
The blower should be selected for paired flow and pressure cases, not a single nominal value. Check minimum, normal and maximum flow, source-pressure variation, destination pressure, temperature, and credible filter loading. The selected model’s operating point must remain within its speed, absorbed-power and temperature limits.
Theoretical volumetric flow can be expressed as:
Theoretical Volumetric Flow
where Vrev is the displaced volume per revolution and N is rotational speed. Actual flow can be represented as:
Actual Volumetric Flow
Here, ηv is volumetric efficiency, which accounts for internal slip and other effects that reduce delivered volume. It varies with the machine and operating conditions; the final value should come from manufacturer performance calculations for the specified gas.
Compatibility, Containment and Controls
Gas compatibility is a package-level issue. Review casing and rotor materials, coatings, elastomers, shaft seals, gaskets and flexible connections against the gas and any liquid that may form. Corrosivity can change when moisture condenses. Deposits can also affect clearances, temperature and maintenance intervals.
Set a measurable leakage requirement where the gas is toxic, flammable, corrosive or environmentally controlled. Define whether the requirement applies while the blower is stopped, running, or both. A seal arrangement should be selected for the specified gas, pressure, temperature and allowable leakage. Purge or vent systems, when required, need compatible gas, monitoring and a defined response to loss of supply.
The complete process design should address gas detection, ventilation, hazardous-area electrical requirements, isolation, non-return protection and relief discharge routing where applicable. These measures are not established by the blower alone. Start-up and shutdown logic should also account for purging, gas composition changes, loss of flow and abnormal pressure or temperature.
Inlet separators or filters may be required to protect the machine from liquid droplets and particles. Coolers, dryers and downstream treatment equipment can add pressure loss and may create condensate that needs controlled drainage. Their condition and operating range belong in the blower duty calculation.
Preparing a Technical Enquiry
Provide enough information to calculate the actual gas duty and confirm the complete package boundary:
- Gas composition and credible operating variations.
- Required flow, reference pressure and temperature, and dry or wet basis.
- Blower inlet and discharge pressures and temperatures.
- Pressure losses through piping, valves, filters and process equipment.
- Moisture, condensable vapours, liquid carryover and particulates.
- Required leakage limit, seal or purge requirements and vent destination.
- Minimum, normal and maximum operating cases, including start-up and shutdown.
- Control method, turndown, operating hours and site conditions.
- Hazardous-area requirements and specified protection measures.
Pasifik Blower can assess a proposed positive-pressure duty against model-specific performance data. Confirmation should cover gas compatibility, actual inlet flow, differential pressure, pressure ratio, speed, absorbed power, temperature and sealing configuration. A standard air curve alone does not establish suitability for process-gas service.
Glossary
Actual inlet volume flow: Gas volume evaluated at the blower’s inlet pressure, temperature and composition. It is the appropriate flow basis for comparison with performance data at matching inlet conditions.
Differential pressure: Difference between pressure at the blower’s discharge and suction flanges. It is evaluated with flow, speed and temperature to confirm the operating point.
External compression: Pressure equalization that occurs when transferred gas reaches the blower discharge and meets the higher system pressure. It is distinct from substantial compression inside the rotor chamber.
Molar mass: Average mass per mole of a gas mixture, calculated from the mole fractions and molar masses of its components. It contributes to gas-density and mass-flow calculations.
Pressure ratio: Absolute discharge pressure divided by absolute suction pressure. Gauge pressures are not used to calculate this ratio.
Volumetric efficiency: Ratio of actual delivered volume to theoretical displacement under stated conditions. Internal slip and operating conditions affect its value.