Thermoforming Vacuum Systems: Roots Machine Suitability Guide

Thermoforming vacuum systems must reach the required absolute pressure within the forming cycle while staying inside equipment limits. Depending on the equipment and product, forming may be accomplished by vacuum, positive air pressure, mechanical assistance or a combination of these methods.

Vacuum is one of the most important process utilities in conventional thermoforming. Once the heated sheet has been positioned and sealed around the mold, air must be removed from the space between the sheet and the mold surface. The resulting pressure difference forces the softened plastic against the mold contours.

The pressure differential acting on the sheet can be expressed as:

Pressure Differential and Forming Force

Δp  =  patm  −  pmould
The theoretical forming force acting over a defined projected area is:
F  =  Δp  ×  A
where:
  • Δp = pressure differential acting on the plastic sheet
  • patm = atmospheric pressure
  • pmould = absolute pressure inside the mold cavity
  • F = total forming force
  • A = projected forming area

These relationships show why both the final vacuum level and the time required to reach that vacuum are important. A vacuum system may eventually reach an acceptable pressure but still be unsuitable if it cannot remove the mold air within the available forming cycle.

Vacuum Performance in Thermoforming

The vacuum requirement of a thermoforming machine cannot be defined by pressure alone. The complete duty includes mold volume, evacuation time, leakage rate, forming temperature, sheet thickness, vacuum-port arrangement and pipeline resistance.

Thin-gauge packaging machines generally operate at very short cycle times. Their vacuum systems must therefore respond almost immediately when the forming valve opens. Heavy-gauge equipment may have longer cycles, but it can involve larger molds, greater internal volumes and more complex air evacuation paths.

The vacuum equipment must provide sufficient effective pumping speed at the mold—not merely a high nominal flow rate at atmospheric conditions. Long or undersized vacuum lines, restrictive valves, contaminated filters and insufficient vacuum-port area can significantly reduce the useful capacity available at the machine.

An approximate evacuation-time relationship for a sealed volume is:

Theoretical Evacuation Time

t  = 
V
Seff
×  ln
(
p1
p2
)
where:
  • t = theoretical evacuation time
  • V = volume to be evacuated
  • Seff = effective pumping speed at the mold
  • p1 = initial absolute pressure
  • p2 = target absolute pressure

This simplified expression assumes constant pumping speed and neglects leakage, gas heating and flow restrictions. Actual thermoforming systems should therefore be sized with appropriate engineering margins and verified against the vacuum equipment’s performance curve.

Where Roots Blower Technology Fits

A roots blower is a positive-displacement machine that transports a nearly fixed volume of gas during each shaft revolution. In suitable vacuum service, this operating principle can provide high gas-handling capacity and rapid evacuation of relatively large volumes.

However, the term “roots blower” should not be used as though it describes every thermoforming vacuum pump. Dry rotary-vane pumps, oil-lubricated rotary-vane pumps, dry claw pumps, screw vacuum pumps and centralized vacuum systems are also widely used. The correct technology depends on the required vacuum level, pumping speed, operating cycle and process conditions.

Roots technology can be incorporated into a thermoforming vacuum installation in two principal ways.

A vacuum-duty roots blower or exhauster may be used as the primary evacuation machine when the required pressure remains within its approved operating range. This arrangement can be suitable for high-flow, low- or medium-vacuum duties, provided that the blower’s temperature, differential-pressure and power limits are not exceeded.

For duties requiring higher pumping speed at lower absolute pressures, a Roots vacuum booster can operate together with a backing pump. The backing pump establishes the necessary inlet and discharge conditions, while the roots stage increases the system’s pumping capacity within its permitted pressure range. Appropriate controls are required to prevent excessive differential pressure or overheating during initial evacuation.

A standard positive-pressure roots blower should not automatically be applied as a thermoforming vacuum pump. Vacuum-duty construction, shaft sealing, cooling, allowable pressure ratio and operating clearances must all be evaluated for the intended service.

Rapid Evacuation and Vacuum Storage

Many thermoforming machines obtain fast vacuum response through a vacuum receiver tank. The receiver is evacuated between production cycles and connected to the mold through a fast-opening valve when forming begins. Its stored vacuum immediately removes a substantial portion of the mold air, while the vacuum pump or blower restores the required receiver pressure for the next cycle.

This arrangement separates two different design requirements:

The receiver and connecting valve provide the instantaneous evacuation capacity.

The vacuum equipment provides the average capacity needed to restore the system between cycles.

A larger blower does not necessarily compensate for an undersized receiver, restrictive valve or poorly designed vacuum pipeline. Likewise, an oversized receiver may offer little benefit if the pump cannot evacuate it before the next forming cycle.

Receiver volume should therefore be calculated together with mold volume, target pressure, available recovery time and permitted pressure fluctuation. Vacuum lines between the receiver and the mold should be short and adequately sized, with minimal unnecessary bends and restrictions.

Selecting the Correct Vacuum Equipment

Reliable equipment selection begins with a clearly defined duty point. The following information should be established before selecting a roots blower or another vacuum pump:

  • Mold and connecting-pipeline volume
  • Initial and target absolute pressures
  • Maximum allowable evacuation time
  • Number of forming cycles per minute
  • Available recovery time between cycles
  • Expected leakage and seal condition
  • Required pumping speed at the operating pressure
  • Inlet-air temperature
  • Ambient conditions and installation altitude
  • Dust, plastic fines, moisture or condensable vapor content
  • Continuous or intermittent operating mode

Flow rate must be interpreted carefully. A stated capacity in m³/h is meaningful only when its reference conditions are known. Free-air delivery, inlet volumetric flow and standardized gas flow are not interchangeable. For vacuum selection, the manufacturer’s performance curve should show capacity, absorbed power and thermal limits across the relevant suction-pressure range.

The blower must also be protected against process contamination. Plastic dust and trimming particles should be prevented from entering the machine by an appropriately sized inlet filter or separator. Filters require differential-pressure monitoring because progressive blockage can reduce mold evacuation speed while increasing the blower’s operating stress.

Cooling of the formed component should be treated as a separate engineering function. Production molds are commonly cooled through temperature-controlled water channels, while fans or directed airflow may assist cooling on the exposed surface. These cooling devices should not automatically be described as roots blowers. roots equipment should only be associated with cooling when an actual machine design requires its particular combination of airflow and pressure.

Where a vacuum-rated roots machine is considered, evaluate capacity at the required suction pressure and verify booster/backing-pump compatibility, receiver recovery and cycle performance. Atmospheric free-air flow alone does not establish suitability for thermoforming.

Glossary

Backing Pump: The primary pump that receives and removes gas discharged by a Roots vacuum booster. Its capacity affects the booster’s operating pressure, pumping performance and protection limits.
Mold Cavity: The space between the thermoforming sheet and mold from which air is evacuated during forming. Its volume and geometry affect the gas flow needed to reach the target pressure.
Mold-Vent Conductance: A measure of how readily gas flows from the mold cavity through its vents. Restricted vents reduce effective pumping speed at the cavity and can create uneven evacuation.
Roots Booster: A vacuum-pump stage that increases pumping speed within its specified pressure range. It normally operates with a backing pump and must stay within its rated pressure-difference limits.
Vacuum Exhauster: A machine rated to remove gas within a specified vacuum operating range. Its suitability depends on the required flow, suction pressure, gas conditions and operating limits.
Vacuum Forming: A shaping method that uses a pressure difference to draw heated sheet material against a mold. The forming result depends on the sheet’s temperature, the pressure profile and the mold’s venting.
Vacuum Receiver: An evacuated vessel that supplies short-duration peak flow during forming. Its usable contribution depends on its volume, starting pressure and permitted pressure rise.
Vacuum-Hold Phase: The part of the forming cycle during which vacuum is maintained after initial evacuation. It helps keep the sheet against the mold while the part cools or stabilizes.