Rapid Mold Evacuation: Vacuum Capacity, Receivers and Machine Limits

Rapid mold evacuation is needed to form a heated plastic sheet before cooling prevents it from reaching the required geometry. The vacuum system must remove the air between the sheet and the mold quickly, consistently and without creating uncontrolled material movement.

Roots blowers can provide high volumetric capacity in suitable vacuum duties. This makes them potentially valuable for the initial evacuation of large molds, recovery of vacuum receiver tanks and high-throughput systems where a considerable volume of air must be handled during every production cycle.

Their suitability, however, depends on the required absolute pressure. A conventional roots blower designed for low- or medium-vacuum operation must not be expected to produce the same final pressure as a dedicated deep-vacuum pump. The required pressure, flow rate and evacuation time must therefore be evaluated together.

How Rapid Evacuation Affects Thermoforming

After heating, the plastic sheet is transferred to the forming station and sealed around the mold. Once the vacuum valve opens, the pressure beneath the sheet begins to fall. Atmospheric pressure acting on the opposite side moves the sheet toward the mold surface.

The forming operation typically develops through several stages:

  • Air begins to leave the mold cavity and the sheet starts moving.
  • The sheet contacts the larger mold surfaces.
  • Remaining air is removed from corners, ribs and detailed areas.
  • Vacuum is maintained while the material cools sufficiently.
  • The mold is vented and the formed part is released.

The initial stage normally produces the highest volumetric airflow because the mold pressure is still relatively close to atmospheric pressure. As pressure decreases, the gas density and mass flow change. The vacuum source must continue operating effectively throughout the pressure range required by the process.

The approximate effective pumping speed required for a specified evacuation time can be expressed as:

Effective Pumping Speed

Seff  = 
V
t
×  ln
(
p1
p2
)
where:
  • Seff = effective pumping speed at the mold
  • V = total evacuated volume
  • t = permitted evacuation time
  • p1 = initial absolute pressure
  • p2 = target absolute pressure

This equation provides an initial engineering estimate for a sealed volume. It does not include leakage, pipeline pressure losses, valve response, changing pump capacity or air released from the plastic and mold surfaces. An engineering margin must therefore be applied.

The total evacuation time is also influenced by the area of the vacuum holes and channels within the mold. Installing a high-capacity blower cannot compensate for blocked, undersized or poorly distributed vacuum passages. If air cannot reach the mold outlet efficiently, pressure may remain trapped in corners and recessed features even when the main vacuum line reaches the required pressure.

Vacuum-System Design Check

Estimate evacuated volume and conductance before assigning pump capacity; a receiver can support a transient but does not replace the vacuum source.

An approximate capacity relationship is:

Actual Inlet Volumetric Capacity

Qactual  =  Vd  ×  n  ×  ηv
where:
  • Qactual = actual inlet volumetric capacity
  • Vd = displacement per revolution
  • n = rotational speed
  • ηv = volumetric efficiency

Volumetric efficiency is affected by internal leakage, rotor clearances, pressure differential, gas temperature and operating speed. Vacuum performance must therefore be taken from the manufacturer’s verified performance data rather than calculated only from geometric displacement.

Roots technology may be integrated into a thermoforming system in several ways.

A vacuum-duty roots blower can evacuate the mold or a receiver directly when the target vacuum remains within the machine’s approved operating range. This can offer a comparatively simple, oil-free gas path and high capacity for rough-vacuum duties.

A roots blower can also be used to restore vacuum in a receiver between forming cycles. In this arrangement, the receiver supplies the immediate evacuation demand, while the blower operates over the recovery period. The blower capacity is then selected according to the receiver volume, operating-pressure range and time available before the next cycle.

Where lower absolute pressure or greater pumping speed at reduced pressure is necessary, a Roots vacuum booster may be installed upstream of a backing pump. The backing pump creates the pressure conditions required for safe booster operation. Control valves, bypass arrangements or variable-speed control may be needed to prevent excessive differential pressure during the beginning of evacuation.

A roots booster must not normally be started at unrestricted atmospheric inlet conditions unless the equipment has been specifically designed and controlled for this duty. Starting the booster too early can result in excessive motor load, high discharge temperature or an unacceptable pressure differential across the machine.

Vacuum Line and Valve Design

Rapid evacuation requires low resistance between the mold and the vacuum source. Pipeline design can be just as important as blower capacity.

The vacuum line should be:

  • As short as reasonably possible
  • Adequately sized for the initial airflow
  • Free from unnecessary restrictions
  • Connected through a fast-acting valve
  • Protected against plastic particles and dust
  • Properly sealed against atmospheric leakage

A large blower connected through a small valve or narrow pipeline may provide disappointing results because the mold cannot access the available pumping capacity. The pressure measured at the blower inlet can also be significantly lower than the pressure inside the mold during periods of high airflow.

For this reason, pressure measurements taken only at the vacuum machine may not describe the actual forming conditions. Installing an additional pressure sensor close to the mold or vacuum manifold allows the machine controller to monitor the pressure experienced by the process.

Valve opening time should also be considered. A valve that requires a significant fraction of the forming period to reach its full open position can limit the initial evacuation rate. The valve’s effective flow area, actuation speed and pressure rating should be matched to the vacuum line.

If a vacuum receiver is used, it should be installed close to the forming machine wherever practical. Long piping between the receiver and mold increases flow resistance and adds volume that must also be evacuated.

Glossary

Forming Window: The time interval during which the heated sheet remains soft enough to form. It depends on material temperature, sheet thickness, heating uniformity and the time between heating and evacuation.
Initial Evacuation Flow: The gas flow required as mold pressure begins to fall from near atmospheric pressure. Its peak depends on connected volume, valve opening, mold-channel conductance and the pressure profile.
Mold Channel: A passage that connects mold openings to the vacuum manifold. Its dimensions and layout affect flow resistance and pressure uniformity across the mold.
Mold-Vent Area: The combined open area through which gas leaves the mold cavity during evacuation. The effective flow can be lower than the geometric area suggests if openings or channels restrict gas movement.
Mold Venting: The release of vacuum or admission of air used to remove a formed part from the mold. The timing and rate should avoid distorting the part or delaying the next cycle.
Pressure Differential: The pressure difference across the sheet that drives it toward the mold surface. A greater differential can increase forming force, subject to the material and process limits.
Receiver Assist Share: The portion of short-duration evacuation demand supplied by a vacuum receiver. It depends on receiver volume, starting pressure, permitted pressure rise and the vacuum-source response.
Receiver Capacity: The receiver’s ability to support a transient forming demand within its specified pressure range. It depends on usable gas volume and pressure limits, not tank volume alone.