Using roots vacuum boosters for thermoforming can increase pumping speed when paired with a compatible backing pump and matched to its operating range. This arrangement may be considered for large molds, high-speed production lines, central vacuum stations or installations where several thermoforming machines create substantial combined demand.
A vacuum booster is not normally a complete vacuum source on its own. It operates together with a backing pump that removes gas from the booster discharge and maintains an acceptable interstage pressure. The two machines must be selected and controlled as one integrated system.
The use of a roots booster should be based on a verified process requirement. Many thermoforming machines can be served effectively by rotary-vane, dry-claw, screw or other standalone vacuum pumps. Adding a booster becomes technically and commercially reasonable when greater pumping speed, shorter evacuation time or additional central-system capacity is genuinely required.
How a Roots Vacuum Booster Operates
A roots vacuum booster contains two synchronized lobed rotors rotating in opposite directions without internal contact. Gas entering the suction port is trapped between the rotors and casing, transported around the chamber and delivered to the discharge side.
The machine has little or no internal compression in the conventional sense. Most compression occurs when the transported gas volume communicates with the higher-pressure gas at the discharge. This operating principle enables high pumping speeds but can also produce significant thermal and mechanical loading when the pressure difference becomes excessive.
Two pressure relationships are important:
Differential Pressure and Pressure Ratio
- Δp = differential pressure across the booster
- Π = absolute pressure ratio
- pd = absolute discharge pressure
- ps = absolute suction pressure
Both values must remain within the booster manufacturer’s permitted operating envelope. A seemingly acceptable differential pressure can still correspond to an excessive pressure ratio when the suction pressure is low.
The backing pump controls the booster’s discharge pressure. If the backing pump is too small, interstage pressure rises, increasing the load and discharge temperature of the Roots stage. Booster selection must therefore include the capacity of the backing pump at the actual interstage pressure.
Gas throughput can be represented approximately by:
Gas Throughput
- q = gas throughput
- p = absolute pressure
- S = pumping speed at that pressure
Under stable conditions, the gas throughput passing through the booster and backing pump is approximately equal:
Throughput Matching in Booster Systems
- ps = booster suction pressure
- Sb = booster pumping speed
- pi = interstage absolute pressure
- Sp = backing-pump speed at the interstage pressure
This relationship is simplified and assumes comparable temperature conditions. Actual performance should be obtained from the combined booster and backing-pump curves.
Application in Thermoforming Vacuum Systems
During a thermoforming cycle, the vacuum system initially handles a large quantity of air at a pressure relatively close to atmospheric pressure. As evacuation continues, the mold pressure decreases and gas density falls.
A booster may not be permitted to operate at full speed during the initial atmospheric evacuation stage. If it begins operating before the backing pump has reduced the pressure sufficiently, the booster can experience excessive differential pressure, motor current and discharge temperature.
A common operating sequence is:
- The backing pump begins evacuating the system.
- The Roots booster remains stopped, bypassed or operated at reduced speed.
- Suction or interstage pressure reaches the permitted booster starting level.
- The booster starts or accelerates progressively.
- The combined system increases pumping speed at the lower pressure.
- The target mold or receiver pressure is reached.
- Vacuum is maintained for the required forming period.
- The system is isolated, vented or returned to receiver-recovery duty.
This sequence may be controlled by pressure transmitters, a bypass valve, a variable-frequency drive or a combination of these methods.
In receiver-assisted thermoforming systems, the booster and backing pump can evacuate the receiver between forming cycles. The receiver supplies the immediate mold demand, while the staged vacuum package restores the stored vacuum over a longer recovery period.
This arrangement can be particularly effective when the forming event is extremely short but the machine provides adequate time for recovery before the next cycle.
Booster and Backing-Pump Matching
The booster and backing pump should not be selected independently. Their displacement ratio affects interstage pressure, booster loading and the time required to reach the target pressure.
A booster with very high nominal capacity connected to a small backing pump may cause the interstage pressure to rise excessively. This can result in:
- High booster discharge temperature
- Excessive motor current
- Reduced volumetric efficiency
- Activation of the bypass valve
- Extended evacuation time
- Thermal expansion and reduced internal clearance
- Premature bearing, seal or gear deterioration
The backing pump must provide sufficient capacity to remove the gas delivered by the booster throughout the intended operating range.
Suitable backing-pump technologies may include:
- Dry claw vacuum pumps
- Oil-lubricated rotary-vane pumps
- Dry rotary-vane pumps
- Screw vacuum pumps
- Liquid-ring vacuum pumps where process conditions justify their use
- Other vacuum-duty positive-displacement machines
Technology selection depends on target pressure, contamination risk, required cleanliness, maintenance strategy and utility availability.
For clean thermoforming air, dry vacuum equipment can avoid oil contamination in the process gas path. However, oil-free operation does not mean maintenance-free operation. Bearings, gears, seals, filters and drive components still require inspection and servicing.
Control and Protection Requirements
A roots booster installation requires controls that prevent operation outside its approved pressure and temperature limits.
A pressure-controlled start is one option. The backing pump evacuates the system until a specified absolute pressure is reached, after which the booster starts. This is simple but may not provide the smoothest transition in rapidly changing systems.
A bypass valve allows gas to flow around the booster when differential pressure is excessive. As system pressure decreases, the bypass closes and the booster progressively handles more of the gas flow.
Variable-speed control provides another approach. The booster can begin at reduced speed and accelerate as operating conditions become suitable. This can reduce mechanical and electrical stress while allowing the system to respond to changing production demand.
Glossary
Branch pressure loss: The pressure reduction between the central header and an individual forming machine results from pipe friction, fittings, valves and flow through the branch. Excessive loss can leave the machine with insufficient vacuum during peak demand.
Central vacuum header: A shared pipe distributes vacuum from a central station to multiple machines. Its diameter and layout should limit pressure variation as connected machines operate.
Demand diversity: Demand diversity describes how connected machines reach their peak vacuum demand at different times. Accounting for this variation can prevent sizing the central station for the sum of every machine’s individual peak.
Diversity factor: The diversity factor is the coincident system demand divided by the sum of individual peak demands. A value below 1 indicates that the combined peak is lower than the total of all separate peaks.
Header pressure setpoint: The header pressure setpoint is the target absolute pressure maintained in the central vacuum header. The controller uses it to adjust pumping capacity while preserving the vacuum required at the machines.
Local receiver: A local receiver is a vacuum vessel installed near a machine to support short-duration peak demand. It can reduce the effect of long branch piping on the machine’s immediate evacuation requirement.
Standby capacity: Standby capacity is reserve pumping capability available if operating equipment is unavailable. Its required level depends on the production consequences of an outage and the system’s redundancy plan.
Vacuum control station: A vacuum control station coordinates pumps, valves, receivers and pressure measurements in a central system. Its control sequence matches available pumping capacity to demand while maintaining the specified header pressure.