Replacing compressed air with a roots blower for tank agitation changes the distribution system as well as the air source. Many electroplating, anodizing, pickling, cleaning and rinse tanks are initially supplied from a factory compressed-air network. This arrangement may appear convenient because the air infrastructure already exists, but it can be inefficient when a continuous process requires a large volume of air at relatively low pressure.
A roots blower system can generate air closer to the pressure actually required to overcome liquid depth, pipeline resistance and sparger losses. However, a successful conversion involves more than disconnecting the compressed-air pipe and connecting a blower.
Compressed-air nozzles, regulators, branch pipes and spargers may have been designed for a much higher supply pressure and a lower volumetric flow. They may not distribute low-pressure blower air correctly. The complete agitation system must therefore be assessed before the air source is changed.
Evaluating the Existing Compressed-Air System
The retrofit should begin with an operating survey rather than an immediate blower selection.
The survey should identify:
- Number and purpose of the tanks
- Tank dimensions
- Normal and maximum liquid levels
- Solution density and temperature
- Existing air pressure at the main header
- Pressure after regulators
- Air consumption of each branch
- Sparger or nozzle arrangement
- Tank operating schedule
- Maximum simultaneous demand
- Existing agitation problems
- Required surface-treatment quality
- Available space for a blower package
Compressed-air consumption should preferably be measured under normal production conditions. Estimates based only on pipe diameter or valve position can be misleading because the actual flow depends on upstream pressure, restrictions and nozzle geometry.
The assessment should also record how operators currently control agitation. In some plants, regulators and valves have been adjusted gradually over many years without documented airflow values. Different shifts may use different settings for the same process.
Visible bubble intensity is not an adequate measurement of air demand. Large bubbles can make a tank appear strongly agitated even when circulation around the components is poor.
The existing system should be observed under several production conditions, including minimum and maximum numbers of active tanks. This establishes the range the new blower system must accommodate.
Confirming Whether Air Agitation is Appropriate
The retrofit study should confirm that air agitation remains technically acceptable for every connected solution.
A tank should not be connected to the new blower simply because it previously received compressed air. The process owner should confirm the required agitation method and airflow for each bath.
Where air agitation is unsuitable, alternatives may include mechanical circulation, eductor mixing, pumped recirculation or component movement. The selection of these alternatives is a process-engineering decision and should not be made solely as part of blower sizing.
Difference Between Compressed Air and Blower Air
Factory compressed air is normally produced at a pressure much higher than that required for submerged tank agitation. Before entering the tank, this pressure is reduced through regulators, valves, small pipes or nozzle openings.
A roots blower produces a much greater air volume at a lower differential pressure. It is intended to supply sufficient pressure to overcome the actual resistance of the tank and distribution system without first compressing the air to the level used by pneumatic tools.
This difference affects every downstream component.
A compressed-air nozzle may depend on high pressure to create a concentrated jet. When connected to a low-pressure blower, it may receive very little airflow. The result can be weak agitation even when the blower’s total capacity appears sufficient.
Conversely, an open pipe originally supplied with throttled compressed air may pass excessive blower airflow unless it is redesigned and balanced.
The conversion must therefore compare the pressure and flow requirements of the air-distribution devices with the verified operating range of the proposed blower.
Inspecting the Existing Spargers
Existing spargers should not automatically be reused.
A sparger designed around numerous very small openings may require more pressure than the proposed blower can economically provide. A sparger with a very large total opening area may offer too little resistance to distribute air evenly.
Long spargers supplied from one end can produce uneven airflow, particularly when their internal diameter is too small. Air may escape strongly through openings near the inlet while the remote end receives insufficient pressure.
Before commissioning the new blower, blocked openings should be cleaned without enlarging them. If mechanical cleaning has changed hole sizes over time, replacement may be more reliable than attempting to rebalance a damaged sparger.
The sparger material must also tolerate the process solution, bath temperature and blower discharge-air temperature. Existing flexible hoses and plastic connections may have been suitable for cool, expanded compressed air but not for warmer blower discharge air.
Redesigning the Air Distribution Network
Compressed-air networks commonly use relatively small pipes because the air is transported at high pressure. A low-pressure blower system usually requires larger pipes to carry the necessary volumetric flow without excessive pressure loss.
The main header should be sized for the combined airflow of all simultaneously active tanks. Individual branches should be sized for their required flow and permitted pressure loss.
The layout should minimize unnecessary bends, restrictions and partially open valves. Valves selected for compressed-air service may have flow passages that are too restrictive for a high-volume blower system.
Tanks with substantially different liquid depths may be better connected to separate pressure groups. Supplying shallow rinse tanks from the pressure required by a deep anodizing bath can create unnecessary throttling and energy consumption.
The new distribution system should also prevent condensate accumulation and process-liquid backflow. Headers should remain above maximum tank liquid level where practical, and low points should include appropriately designed drainage.
Establishing the Blower Duty Point
The blower duty point consists of the required airflow and the total differential pressure it must overcome.
The airflow should be based on the maximum credible simultaneous demand rather than the simple sum of every installed tank if they do not all operate together.
The design allowance should cover realistic variations without becoming an excuse for excessive oversizing. Selecting a blower far above the calculated requirement can create difficult control, high noise, unnecessary motor power and excessive relief-valve operation.
The blower manufacturer should receive clearly defined airflow reference conditions. Normal cubic metres, standard cubic metres and actual inlet cubic metres are not necessarily equivalent.
Installation altitude and maximum inlet temperature should also be specified because they affect air density, delivered mass flow, motor loading and cooling.
Selecting the Blower and Motor
Roots blowers are positive-displacement machines. Their delivered volume is primarily related to blower
Motor selection should be based on the highest credible operating pressure, not only the expected average pressure. Progressive sparger blockage or incorrect valve positioning can increase the absorbed power.
The motor should have an appropriate service margin, but excessive oversizing should be avoided. A much larger motor does not increase blower capacity by itself and may operate inefficiently at low load.
Equipment exposed to a corrosive metal-finishing atmosphere should have suitable coatings, enclosure protection and ventilation.
Air Quality During the Conversion
Replacing compressed air with a roots blower changes the source of the process air.
Factory compressed air may pass through centralized dryers and filters. A dedicated roots blower normally draws ambient air directly from its surroundings. Although lubricant is not injected into the blower compression chamber, the air can still contain dust, moisture, chemical vapor or mist drawn through the intake.
Inlet filtration should be selected according to the process sensitivity and surrounding environment. The filter must have enough area to provide the required airflow without excessive restriction.
The existing air pipes should be cleaned or replaced before the new system is commissioned. Corrosion products, oil deposits and construction debris must not be blown into the treatment baths.
If the previous compressed-air network contains oil aerosol, the old branches may remain contaminated even after the compressor connection is removed.
Capacity Control
Compressed-air agitation is often controlled by adjusting individual regulators or small valves. A roots blower system requires a different control philosophy.
Closing tank branches while a fixed-speed positive-displacement blower continues operating causes system pressure to rise. The blower output cannot be controlled efficiently by simply throttling its discharge.
A variable-frequency drive can reduce blower speed when fewer tanks are operating. The permitted minimum speed must still be respected to maintain adequate cooling and lubrication.
Main-header pressure may be used as a control signal, but it does not confirm that every branch receives the correct airflow. Critical tanks should have individual airflow monitoring or another reliable method of verifying agitation.
The pressure-relief valve is required for safety but should not be used as a normal capacity-control device. Continuous relief means that energy is being consumed to produce air that does not reach the process.
Maintaining Production During Installation
A retrofit must often be completed without a long production shutdown.
The installation plan should identify:
- New blower location
- Route of the larger air header
- Tank connection sequence
- Temporary air-supply requirements
- Electrical installation
- Control-system modifications
- Cleaning and flushing procedures
- Planned shutdown period
- Commissioning responsibilities
Where possible, the new header can be installed alongside the existing compressed-air network. Individual tanks can then be transferred during planned production stops.
Temporary cross-connections require careful design. High-pressure compressed air must not be introduced directly into a low-pressure blower header without suitable regulation, isolation and protection.
The blower must also be protected from compressed air flowing backward into its discharge connection. Separate non-return and isolation arrangements may be necessary during the transition.
The old compressed-air supply should not be permanently disconnected until the new blower system has demonstrated acceptable operation under representative production demand.
Glossary
Air-Distribution Retrofit: Modification of pipes, outlets or layout to suit a new airflow and pressure regime. The design should provide the required air distribution across connected process equipment.
Before-and-After Test: Measurement procedure that compares system performance before and after a retrofit. The comparison should use equivalent operating conditions or account for differences in load and production.
Compressed-Air Network: Plant-wide system for generating, treating, storing and distributing compressed air. It can include compressors, filters, dryers, receivers and distribution piping.
Demand Condition: Defined combination of air demand and plant operating state used to assess system performance. It identifies the conditions under which the required flow and pressure apply.
Header Conversion: Redesign of an existing air distribution network for a different pressure and flow regime. The review should account for pipe capacity, branch demand and connected equipment.
Pressure Regulator: Valve that reduces and controls downstream pressure from a higher-pressure source. Its flow capacity and pressure losses should suit the connected system.
Retrofit Baseline: Verified pre-project data used to evaluate retrofit performance. It should represent normal operating conditions and include the measurements needed for comparison.
Verified Saving: Energy reduction supported by comparable measurements taken before and after a retrofit. The comparison should account for changes in production, operating hours and system demand.