Roots Blower Terms Beginning with L

This page defines roots blower terms beginning with L, including labyrinth seals, leakage rate, line clearing, lobe timing, and low-pressure boosting.

Labyrinth Seal: Non-contacting seal that restricts gas flow through a sequence of narrow clearances. It limits leakage but does not, by itself, establish zero leakage.
Lagoon Cell: One basin within a treatment system arranged as one or more sequential or parallel ponds.
Laminations: Internal structural defects, layers, and voids within the extruded clay body caused by trapped air pockets that fail to escape before the clay is forced through the die.
Lance: A specialized, heat-resistant steel pipe or nozzle used to safely guide and inject the pneumatically conveyed powder and carrier gas directly into the molten steel bath.
Landfill Wellfield: Network of extraction wells and connecting pipes that collects gas from waste layers. Its performance depends on well placement, waste conditions and the collection system.
Latent Heat Of Vaporization: Energy required to convert liquid into vapor at specified conditions. Evaporation draws this energy from the bath and can contribute to cooling.
Leach Aeration Grid: Piping and outlets that distribute process air beneath or through a leach heap. Its layout and resistance affect how evenly the air reaches different zones.
Leachate: Liquid that drains from composting material and may carry dissolved or suspended constituents.
Leachate: Solution that drains from the heap after contacting the ore. It contains dissolved constituents and is collected for downstream recovery or treatment.
Leachate: The heavily contaminated liquid that drains out of the composting feedstock, rainwater, or condensate, which can collect in floor channels and requires dedicated drainage to prevent pipe blockages.
Lead-Lag Control: Strategy that assigns one blower as the lead unit and starts another when demand increases or the lead unit becomes unavailable. Lead assignment can be rotated to distribute operating hours.
Lead-Lag Controller: An automated, energy-saving control system for parallel blower setups that intelligently stages multiple machines (turning them on or off in sequence) to match real-time plant demand.
Lead-Lag System (Staging): An automated control logic for multiple parallel blowers that intelligently sequences them to turn on (lead) or remain off/standby (lag) strictly according to real-time plant demand, maximizing energy efficiency and rotating operating hours.
Lead-Lag Vessels: Two treatment vessels arranged in series so the second provides polishing capacity and breakthrough protection.
Leakage: Unintended gas flow through joints, seals, valves or equipment that consumes capacity and can affect dust containment.
Leakage Collection Header: Piping that combines leakage gas from one or more feeder vents.
Leakage-Flow Curve: Measured relationship between rotary-valve leakage and pressure difference for a specified valve configuration and operating condition.
Leakage Rate: Quantity of gas escaping or entering per unit time. Its reference pressure, temperature and gas composition should be stated.
Leak-Isolation Test: A procedure that isolates system sections to locate the source of air ingress. Comparing pressure changes across sections helps identify which component or connection needs inspection.
Leak Rate: The quantity of air entering a system per unit time under stated conditions. It is used to assess vacuum-system integrity and should be reported with its units and test pressure.
LEL: The lower explosive limit, below which a fuel-vapor concentration is too lean to propagate combustion under stated conditions.
Lentic System: A standing or slowly moving water body such as a lake, reservoir or pond.
Level Trips: Automated, non-bypassable safety instruments installed within knock-out vessels or separators that immediately stop the blower, close gas isolation valves, and prevent automatic restarts if accumulated liquid levels rise dangerously high.
Lifecycle Cost Basis: Comparison of equipment, installation, maintenance and replacement costs against documented operating benefits.
Lift-Gas (Argon Injection): Pressurized argon injected specifically into the up-leg snorkel to decrease the apparent density of the molten steel column, which actively drives the upward circulation of the metal into the vacuum vessel.
Lift Station: A facility that raises wastewater from a lower to a higher hydraulic elevation; its pumps, wet well, controls and force main form the liquid-conveyance system.
Light Textile Fraction: Synthetic fabric fibers and fluff separated from the tire’s internal cord structure, notorious for wrapping around rotary feeders and forming stubborn, difficult-to-clean layers on dust filters.
Limiting Current Density: Maximum current density associated with transport of an electroactive species to an electrode under specified conditions. The equation is an idealized transport limit and does not by itself define the production setpoint.
Line-Clearance Criterion: Verified condition used to determine whether conveying material has been removed from the pipeline.
Line Clearing: Controlled removal of residual powder from a conveying line after a stop or interruption. The sequence should suit the material, system arrangement and restart procedure.
Line-Clearing Sequence: A programmed operational phase where pure conveying air is pumped through the pipeline after a transfer is complete to purge residual material and prevent batch cross-contamination.
Line-Clearing Time: The specific programmed duration at the end of a pneumatic conveying cycle where pure air is blown through the pipeline to purge residual material before the next batch is transported.
Line Hold-Up: Material that remains inside the conveying route instead of reaching the receiver.
Line-Inventory Correction: Adjustment that accounts for material entering or leaving the test boundary while solids remain in the pipeline.
Line Purging: A mandatory changeover procedure where the entire pneumatic pipeline and receiver system is blown completely clean of any residual pellets or dust to prevent cross-contamination when switching to a different resin color or formulation.
Line Surging: Severe, rhythmic fluctuations in pneumatic pipeline pressure caused by the repeated accumulation and sudden clearing of material deposits when conveying velocity falls below the stable transport threshold.
Lining Bond Failure: Separation of a lining from its substrate, which can expose the base pipe or release material into the line.
Liquid Backflow: Reverse movement of process liquid into an air pipe or blower connection. It can expose components to aggressive chemical conditions and requires inspection before restart.
Liquid Carryover: The dangerous, uncontrolled ingress of free liquids, un-separated aerosols, or condensed vapors into the blower’s close-clearance compression chamber, which can cause severe mechanical damage, hydraulic lock, and seal failure.
Liquid-Displacement Method: Measurement approach that uses a liquid to determine material volume under stated conditions.
Liquid Slug: A concentrated volume of liquid moving through a pipe rather than dispersed droplets. A slug can result from drainage failure or a process upset and may overwhelm downstream protection.
Live Capacity: Material inventory expected to discharge within the defined operating sequence.
Load-Duration Profile: Distribution of operating hours across different demand levels.
Loaded Conveying Point: An operating condition recorded with material flowing, including its solids rate, airflow and pressure.
Loaded Duty Point: The operating condition measured with material entering the conveying stream, including its effect on flow and pressure.
Loaded Filter: A filter in service after captured contaminants have increased its resistance.
Loaded-Line Airflow: The airflow required while material is being conveyed through the defined route at a stated solids rate.
Loaded-Line Restart: Restart procedure for a pipeline that may contain settled solids after shutdown.
Loaded-Loss Estimate: Assessment of pressure demand associated with conveying solids, in addition to air-only resistance.
Loaded Operating Point: A measured condition during material conveying that pairs airflow and differential pressure with a stable, documented solids rate.
Loaded-Route Case: A set of airflow, pressure and solids-rate measurements recorded for the same loaded conveying condition.
Loaded Test Point: Operating condition recorded while material is being conveyed at a defined rate.
Loaded-Test Repeatability: Consistency of measured throughput and pressure across repeated tests at the same operating conditions. Poor repeatability should be investigated before results are used to set the design duty.
Loaded-To-Empty Pressure Difference: Comparison between pressure measurements during material conveying and operation with the route cleared under stated conditions.
Load-Following Response: How quickly blower flow adjusts to a change in process gas demand.
Loading Rate: Rate at which stress is increased during a compaction test.
Load Line: Representation of the system’s required flow and vacuum across its operating range.
Load Lock: A chamber that transfers substrates between atmosphere and the process vacuum without venting the main chamber. Its evacuation time can affect production throughput.
Load Sharing: Distribution of process demand among parallel blower units. The control sequence should keep operating machines within their approved ranges while preserving required standby capacity.
Lobe Timing: Synchronization of the rotors by timing gears so they rotate with the designed clearances.
Local Actual Velocity: Gas velocity calculated for a specific pipe section using its internal area and the gas volume at local pressure and temperature.
Local Actual Volume: Gas volume flow at the pressure and temperature present in a specific pipeline section.
Local Bore Restriction: Reduction in available internal flow area caused by a fitting, joint, deposit or deformation.
Local-Exhaust Permissive: Control condition that allows a process-related device to operate only when the designated exhaust system is available. The interlock response to loss of exhaust should be defined in the project control logic.
Local Exhaust Ventilation: Engineered ventilation that captures and removes airborne contaminants near their source before they disperse into the workplace.
Local Exhaust Ventilation: Source-capture system that removes hazardous mist or vapor from the workplace.
Local Extraction: A targeted dust containment strategy using dedicated suction points positioned immediately at material transfer or unloading zones to capture hazardous fines before they disperse.
Local Filling Load: Concentrated action caused by product momentum or deposition near a silo inlet.
Local Gas Expansion: The increase in actual gas volume as pressure falls along a conveying line. It can change velocity in a constant-bore section.
Local Gas State: The pressure and temperature at a specified pipeline location. These conditions determine the actual gas volume used in the local velocity calculation.
Local Gas Volume: The actual volume occupied by the gas at a defined pipeline or receiver pressure and temperature.
Local Mass-Transfer Coefficient: Factor describing the rate at which a species moves between the bulk electrolyte and an electrode surface. Its value depends on the local flow and surface conditions.
Local Pressure Peak: A concentrated pressure that exceeds the surrounding distribution because of geometry or flow behaviour.
Local Receiver: A local receiver is a vacuum vessel installed near a machine to support short-duration peak demand. It can reduce the effect of long branch piping on the machine’s immediate evacuation requirement.
Local Slip Ratio: A comparison between particle and gas speeds at a defined location. The numerator, denominator and measurement method must be stated.
Local Velocity Transition: Change in actual gas velocity caused by a bore, pressure, temperature or flow change.
Lockout Procedure (LOTO – Lockout/Tagout): The strict industrial safety protocol required before any maintenance begins, ensuring the machine is electrically isolated, depressurized, purged of toxic gases, and physically locked to prevent accidental, fatal restarts.
Longitudinal Pressure Survey: Pressure measurements taken at defined points along the conveying route. The results help compare calculated losses with the installed system.
Long-Line Expansion Effect: The change in actual gas volume as pressure falls along a conveying route. It can alter local velocity and the pressure profile.
Long-Radius Bends: Specialized pipe elbows with a wide curvature designed specifically for pneumatic conveying to reduce the impact angle and friction as pellets change direction, minimizing pellet degradation and streamer formation.
Loop Check: Test that verifies an instrument signal from its field device through the control system to the intended indication or action. It can identify wiring, scaling, configuration or logic errors.
Loop Heat Balance: Accounting of heat added to and removed from gas circulating through the closed system.
Loose Density: Mass of powder per unit volume after filling without the specified tapping or compaction procedure.
Loss-In-Weight Feeder: A gravimetric feeder that estimates material delivery from the decrease in hopper weight over time.
Loss-In-Weight Measurement: A high-precision continuous weighing and feeding technique used to accurately meter minor dry additives into foundry mixers without pressure fluctuations.
Loss-Of-Signal Response: Defined equipment action when a required control or measurement signal becomes unavailable.
Lost-Foam Casting: A precision metal-casting process using an expendable polymer foam pattern embedded in unbonded sand, which is directly vaporized and replaced by molten metal during pouring.
Lotic System: A flowing water body such as a river, stream or channel.
Low-Damage Operating Window: Verified range that maintains stable transport while meeting the product-quality limit.
Lower-Bend Transition Zone: Combined design area covering the bottom of the downpipe, its bend and the following horizontal section.
Low-Flow Permissive: A control condition that prevents material feed until airflow has reached the approved minimum.
Low-Point Drain: A controlled drainage point where condensate naturally collects in sloped piping.
Low-Pressure Boosting: The application of roots blowers to incrementally increase the pressure of compatible gas streams from declining wellheads or gathering networks, strictly limited to duties that remain within the blower’s verified thermal and mechanical capabilities.
Low-Pressure Verification Point: A measured operating condition used to confirm material transport within the proposed low-pressure system range.
Low-Velocity Pockets: Specific zones within the pneumatic pipeline—often near sudden diameter changes or misaligned joints—where the airstream slows down, causing heavy ceramic minerals to drop out and form blockages.
Low-Velocity Zones: Specific areas within the pneumatic pipeline network where air speed drops below the minimum transport threshold, causing unwanted settling and accumulation of carbon black particles.
LPCVD: Low-pressure chemical vapor deposition, a thermal thin-film process conducted below atmospheric pressure.
Lubrication Interval: Manufacturer-defined time or operating-hour period between lubricant service actions. The applicable interval depends on the machine instructions and operating conditions.