Tablet Press: A heavy-duty pharmaceutical manufacturing machine that receives pneumatically conveyed blended powders and mechanically compresses them into solid dosage forms.
Tail Gas: Residual gas stream leaving an upgrading or separation process.
Tailings: Residual material remaining after mineral recovery.
Tangential Entry: A specific receiver design feature where the pellet-laden air stream enters the vessel at an offset, horizontal angle, forcing the material into a gentle cyclonic flow against the walls to dissipate kinetic energy without destructive perpendicular impacts.
Tangential Impact: Collision in which a particle contacts a surface at a shallow angle and may continue sliding along it.
Tangential Inlet: A specifically engineered, off-center entry port on a receiver vessel that forces incoming lightweight flakes into a circular, cyclonic motion to slow them down gently without direct impact.
Tank Agitation: Controlled movement of liquid within a tank using air, pumping or mechanical equipment. The method is selected to meet the required mixing or circulation duty.
Tank Freeboard: Vertical space between the normal liquid surface and the tank rim or cover. It provides room for liquid movement and helps limit splashing.
Tank-Demand Signal: Control input indicating whether a tank requires agitation and the associated operating demand. It may come from a recipe, sequence controller or verified operator selection.
Tanker Aeration: Distribution of air within a bulk tanker to loosen stored powder and support controlled discharge into the transfer line.
Tanker Unloading Package: Blower, connections and controls configured to transfer bulk material from a road tanker. Its operating limits and procedure must match the tanker and receiving system.
Tap Endpoint: Defined condition used to decide when the tapping procedure is complete.
Tapped Density: Mass of powder per unit volume after a defined tapping procedure.
Tapping Amplitude: The displacement applied to the sample during each tap in the test procedure.
Tapping Frequency: The rate at which taps are applied during the measurement.
Tar And Naphthalene: Sticky, heavy hydrocarbon by-products commonly found in raw coke-oven gas that can condense, foul the blower internals, and cause catastrophic mechanical failure if not properly conditioned upstream.
Target Local Velocity: Gas velocity specified for a particular pipe section under defined local conditions.
Target Pre-Sputtering: A controlled plasma step that conditions or cleans the target before deposition. It contributes to the pump train’s process-gas load.
Target Sections: Replaceable, reinforced pipeline segments installed specifically at high-velocity directional changes to absorb the brunt of abrasive mineral impacts, keeping maintenance localized and manageable.
Tariff Assumption: Electricity-price basis applied to convert energy consumption into an estimated operating cost.
Telemetry: Remote communication and monitoring technology utilized at isolated wellhead installations to transmit real-time data on suction pressure, separator levels, and gas detection back to operators.
Temperature Class: Gas or vapor equipment classification based on its maximum surface temperature relative to the ignition temperature of the applicable atmosphere. Dust applications often require a separate maximum-surface-temperature assessment for cloud and layer conditions.
Temperature Gradient: Change in temperature across a specified distance or between measurement locations. Comparing gradients within a tank helps identify uneven heating or circulation.
Temperature Lift: The temperature difference between compressed vapor condensing on the heating side and liquid boiling on the process side. It determines the available heat-transfer driving force.
Temperature Profile: A series of water-temperature measurements taken at different depths.
Temperature Recovery Time: Period needed for the bath to return to its specified temperature range after a defined disturbance. The result depends on the bath’s thermal capacity, heat input, losses and mixing.
Temperature Trip: An automated, non-bypassable safety interlock that immediately shuts down the blower if internal or discharge temperatures exceed safe mechanical limits, preventing catastrophic rotor expansion and seizure.
Temperature Uniformity: Degree to which temperature remains consistent across defined tank locations.
Tempering Quench Systems: High-capacity industrial cooling setups requiring massive volumes of carefully distributed air that typically exceed the practical operating range of standard roots blowers.
Terminal Filter Resistance: Pressure loss across the receiver filter at its specified end-of-service condition.
Terminal Gas Load: The conveying-gas volume reaching the receiver and its vent or filtration system under a defined operating condition.
Test Cutoff Criterion: A pre-agreed condition that stops a trial before unstable or unsafe conveying is treated as a valid operating point.
Test Decision: Choice to proceed using existing evidence, perform targeted component testing or run a representative conveying trial.
Test Endpoint: The defined point at which tapping or measurement stops and the final density is recorded.
Test Envelope: The measured range of material and operating conditions covered by a trial, with stable and non-stable regions identified.
Test Matrix: A project record that connects each handling risk to the test, material condition and decision it supports.
Test Protocol: The documented procedure, apparatus and operating conditions used to produce a test result.
Test Rig Scaling Boundary: Documented statement of which production effects a pilot rig represents and which it does not.
Test-Bed Depth: Height of powder in the test column before aeration begins.
Test-Method Drift: A change in results caused by differences in equipment, procedure or laboratory practice over time.
Test-Point Validity: Confirmation that the material, route and synchronized measurements support the reported test result.
Test-Rig Scale-Up: Use of conveying test results to estimate performance in a larger or longer installation. Its validity depends on how well the test and plant material, geometry and operating conditions correspond.
Test-To-Plant Mismatch: Difference between the tested and proposed systems that may affect scale-up.
Thermal Balance: Accounting of heat added to and removed from the circulating gas during operation.
Thermal Equilibrium: Condition in which process temperatures have stabilized sufficiently for repeatable comparison.
Thermal Expansion: Dimensional change in a conveying line as its temperature changes.
Thermal Expansion: The physical growth and dimensional shifting of downstream pipelines, valves, and filter housings during high-temperature steam sterilization cycles, which must be accommodated in the system’s mechanical design.
Thermal Gradient: The rate of temperature change with depth or horizontal distance.
Thermal Growth Allowance: Design provision for changes in component dimensions as operating temperature changes.
Thermal Limit: The maximum operating temperature or temperature condition allowed for the selected machine.
Thermal Load: Rate of heat addition or removal required by the process.
Thermal Mapping: Planned measurement of temperature at multiple locations in a vessel or process area. It is used to assess spatial uniformity under defined operating conditions.
Thermal Mass Sensor: Sensing element that infers gas mass flow from heat transfer to the moving gas. Deposits and changes in gas composition can affect its output.
Thermal Operating Limit: The maximum permitted temperature for the selected blower or package under its defined operating conditions. It must be checked together with pressure and speed.
Thermal Oxidation: Destruction of combustible contaminants by controlled high-temperature oxidation.
Thermal Parameters: The specific temperature boundaries—including inlet heat, compression heat, and ambient limits—that must be historically tracked to ensure the blower remains within its mechanical operating envelope.
Thermal Profile: Set of gas and equipment temperatures recorded or estimated along the complete process route.
Thermal Reaction Stage: The initial, high-temperature combustion chamber within the SRU where the hydrogen sulfide and blower-supplied air mix and ignite, requiring extremely stable pressure and precise stoichiometry.
Thermal Sand Reclamation: An advanced sand-recycling process that uses high-temperature thermal treatment to burn off and remove residual organic chemical binders from used foundry sand.
Thermal Stabilization Period: The time required for equipment and pipe temperatures to reach representative operating conditions.
Thermal Stratification: Formation of liquid layers at different temperatures within a tank. It can leave the sensor reading unrepresentative of conditions around the workpiece.
Thermal Stratification: Layering of water by temperature and density that influences the water moved upward by rising bubbles.
Thermophilic Activity: The high-temperature phase of the composting process where heat-loving microorganisms rapidly decompose organic matter, requiring maximum airflow for both oxygen supply and heat removal.
Thermoplastic Pressure Derating: Reduction in allowable thermoplastic pipe pressure as operating temperature increases. The applicable rating must be confirmed for the pipe material and service conditions.
Throat: The venturi’s restricted passage where gas velocity increases and static pressure falls.
Throttle Valve: A valve that changes gas-flow conductance between a chamber and its pumping system to regulate pressure. Its position affects the effective pumping speed available at the chamber.
Throughput Acceptance Criterion: The agreed method and conditions for deciding whether the required solids rate has been achieved. It should specify measurement duration and acceptable variation.
Throughput Turndown Range: The minimum-to-maximum solids-rate interval required in operation. It helps define feeder control and blower operating requirements.
Throwing Power: Ability of a plating process to deposit metal across surfaces with different electrical and geometric access to the anode. Bath chemistry and cell geometry influence the result.
Time Consolidation: Increase or change in bulk-solid strength during storage under load.
Timed Aeration: An automated control method that injects fluidizing air into the silo for specific, pre-programmed durations rather than running the blower continuously.
Timing-Gear Damage: Wear or failure of the precision gears that keep the Roots blower rotors perfectly synchronized; damage here instantly alters the internal clearances and leads to severe vibration and rotor contact.
Timing-Gear Wear: The physical degradation of the precision gears responsible for keeping the Roots blower’s two rotors perfectly synchronized; failure here is often signaled by a rapid increase in vibration or internal mechanical contact noise.
Tonal Noise: A specific, narrow-band, high-pitched acoustic emission characteristic of positive-displacement roots blowers that often requires targeted silencers and acoustic enclosures to manage workplace noise exposure.
Top Particle Size: The largest relevant particle dimension used to check feeder openings, clearances and possible blockage points.
Total Kjeldahl Nitrogen (TKN): Organic nitrogen plus ammonia nitrogen measured by a defined analytical method; it does not include nitrate or nitrite nitrogen.
Total Oil: Combined oil content from aerosol, vapor and liquid phases under a stated test method.
Toxic Inhibition: Reduction in biological activity caused by substances that adversely affect the treatment microorganisms. Adequate airflow may not restore treatment performance while the inhibiting substance remains in the process.
Trace Contaminants: Minor chemical components or impurities present in the process gas stream that can disproportionately dictate specialized seal materials, compatible coatings, or advanced metallurgy.
Trace Protection (Heat Tracing): Electrical heating cables or elements wrapped around exposed condensate drains, traps, and pipes to prevent the collected liquid from freezing during winter or cold weather conditions.
Transferability Label: Status assigned to earlier data to show whether they apply directly, with limits or only as background.
Transferable Evidence: Test observations that can inform a different system, while not automatically proving its capacity or operating point.
Transformation Product: A compound formed when a parent substance changes through biological, chemical, physical or treatment reactions; its fate and toxicity may require separate evaluation.
Transient Case: Short-term, unstable operating states (like the initial seconds of pump-down or a sudden lance blockage) that create temporary power peaks, which must not be used to calculate the system’s long-term average energy efficiency.
Transient States: The dynamic, non-steady operational phases of a conveying system—such as start-up, shutdown, line purging, and batch changeovers—which often produce the most extreme pressure demands.
Transition Angle: Angle of the expanding pipe wall between the smaller and larger internal diameters.
Transition Continuity: Condition in which adjoining pipe sections meet without an internal ledge or unintended restriction.
Transition Geometry Record: The documented dimensions and construction details of a pipeline diameter transition.
Transition Inspection Access: Provision that allows the internal profile and condition of a pipe enlargement to be checked.
Transition Location: Point in the route where the pipeline changes from one internal diameter to another.
Transition Taper: Gradually widening fitting that connects two different internal pipe diameters. Its angle, length and internal finish influence flow separation and how solids redistribute after the expansion.
Transmembrane Pressure: Effective pressure difference between the mixed-liquor side and permeate side of a membrane that drives liquid through the membrane barrier, reported with the project’s sign and averaging convention.
Transport Stability Boundary: Lowest tested condition that maintains reliable material movement for the defined route and operating case.
Transport Stability Window: Verified airflow range that supports material movement while meeting product-quality and operating constraints.
Transport-Induced Compaction: Densification of a bulk solid caused by vibration or movement during transport.
Treatability Evaluation: Engineering analysis, laboratory testing or pilot work used to determine whether a defined wastewater stream can be handled by a proposed treatment process under stated operating conditions.
Treatment Media: A porous, moist, and biologically active mixture (such as wood material, bark, mature compost, or mineral support) that contains microorganisms to degrade biodegradable odor compounds.
Trend Deviation: A sustained change from the proven relationship among operating parameters rather than one isolated reading.
Trend Limit: A boundary used to identify a change in results that merits investigation.
Trial Matrix: A structured list of material grades, operating rates, airflow conditions and routes included in a conveying test.
Trip: Protective action that stops equipment when a defined unsafe or damaging condition is detected.
Trip Simulation: Safe test that imitates a trip input to verify the intended shutdown or protective response. It avoids creating the hazardous operating condition the trip is designed to address.
Trip Test: Functional test proving that a protective input causes the required shutdown response.
Turbidity: Loss of water clarity caused by suspended or colloidal material.
Turndown: The usable operating range within which a variable-speed blower can safely reduce its speed and airflow to meet lower biological demands without risking motor overheating or stalling against system resistance.
Turndown Profile: The operational range over which a variable-speed or multi-machine system can safely reduce its capacity to match changing plant demand without relying on excessive throttling or continuous recycle.
Turndown Range: The defined operational spectrum over which a roots blower or centrifugal fan can decrease its airflow output to safely match the changing combustion air demands of a kiln burner.
Turndown Ratio: The defined operational range representing a burner’s maximum to minimum capacity, which the roots blower must seamlessly support through variable-speed control without surging or continuous relief-valve venting.
Tuyeres: The specific nozzles or ports located near the lower section of a cupola furnace through which low-pressure combustion air is injected into the vertical charge.
Type-Approved Plant: A sewage treatment plant tested and certified by the relevant Administration against the applicable marine effluent standard and approval basis.
UEL: The upper explosive limit, above which a fuel-vapor concentration is too rich to propagate combustion under stated conditions.
Uhle Box: Stationary vacuum box positioned against a moving press felt to draw air and water through it. Its airflow demand depends on slot geometry, felt condition, seal condition and machine speed.
Ultimate Pressure: The lowest pressure a pump or pumping station approaches under specified conditions and low gas load. It does not describe how quickly the system removes gas during a process cycle.
Unbonded Sand: Dry, binder-free foundry sand used in vacuum-moulding and lost-foam processes, relying on negative pressure or vacuum containment rather than chemical agents to maintain structural form.
Unconfined Yield Strength: Stress required to fail a consolidated bulk-solid specimen when no lateral confinement is applied.
Underdrain: The filter-floor and distribution system that collects filtered water and distributes backwash water or air across the bed within defined hydraulic and structural limits.
Uniform Extraction: Withdrawal pattern that activates the intended hopper outlet area instead of drawing from one localized region.
Unit Process: A distinct physical, chemical or biological treatment step within a larger treatment train.
Unmetered Air Addition: Gas entering the conveying system downstream of the primary flow meter without being included in its reading.
Unresolved Evidence Item: Missing test, measurement or design input that must be closed before a specified project decision.
Unrestricted Broken Glass: Large, unsorted, and irregularly shaped glass fragments that are completely unsuitable for pneumatic transport and should never be conveyed using roots blowers.
Unverified Operating Case: Material or system condition not covered by test data or a supported calculation.
Upgrading-Skid Interface: The defined connection where a transfer, recycle or auxiliary machine serves a PSA/VPSA package, separately from its principal cycle equipment.
Upset Cases: Abnormal or high-demand operational states—such as a loaded filter, a closed branch, or a changed feed rate—that can shift the blower’s duty point and require predefined control responses.
Upset Conditions: Abnormal, transient operating states—such as sudden feedstock moisture spikes, grade changes, or temperature drops—that cause a rapid, unexpected surge in the volatile gas load, stressing the capacity of the entire vacuum train.
Usable Receiver Volume: The portion of tank volume available between the specified high and low pressure limits. The gas capacity within that range depends on tank volume and the allowed absolute-pressure change.
Utility Tie-In: Connection point where a package receives or returns a plant service such as electrical power, cooling water or instrument air.