Thermoforming Vacuum Demand: Flow, Absolute Pressure and Cycle-Time Analysis

Thermoforming vacuum demand changes through each forming cycle, so peak flow and cycle-average capacity both need evaluation. Successful vacuum generation therefore depends on three connected parameters: the attainable pressure, the effective pumping speed and the time available for evacuation.

Selecting a vacuum pump or roots blower solely from its nominal airflow is not sufficient. The machine must deliver the required capacity at the actual suction pressure while remaining within its permitted differential-pressure, temperature, speed and power limits.

Vacuum Pressure and Forming Force

Atmospheric pressure acts on the outer surface of the heated plastic sheet while the vacuum system reduces pressure on the mold side. This pressure difference produces the force that pushes the material against the mold.

The available pressure differential is:

Forming-Pressure Differential

Δp  =  patm  −  pmould
where:
  • Δp = available forming-pressure differential
  • patm = local atmospheric pressure
  • pmould = absolute pressure inside the mold cavity

The corresponding theoretical force is:

Theoretical Forming Force

F  =  Δp  ×  A
where:
  • F = theoretical forming force
  • A = projected forming area

A lower absolute pressure inside the mold produces a greater pressure differential. However, the relationship is limited by local atmospheric pressure. Vacuum forming cannot generate a pressure differential greater than the surrounding atmospheric pressure.

For this reason, pressure values should always be identified as either absolute or gauge pressure. Confusing these two references can result in serious equipment-selection errors.

The relationship between them is:

Absolute Pressure

pabs  =  patm  +  pg
where:
  • pabs = absolute pressure
  • patm = atmospheric pressure
  • pg = gauge pressure

In vacuum service, gauge pressure is negative. For example, a gauge pressure of −500 mbar at an atmospheric pressure of 1,000 mbar corresponds approximately to:

Percentage Vacuum Calculation

pabs  =  1,000  +  (−500)
pabs  =  500 mbar absolute
The percentage vacuum can be expressed as:
Vacuum (%)  = 
[
patm  −  pabs
patm
]
 ×  100

A reading of −500 mbar gauge therefore represents approximately 50% vacuum when the local atmospheric pressure is 1,000 mbar. It must not be interpreted as an absolute pressure of 500 mbar without confirming the atmospheric reference.

Installation altitude also matters. Atmospheric pressure decreases as elevation increases, reducing the maximum pressure differential available for forming. A system designed using sea-level conditions may consequently produce less forming force when installed at a high-altitude factory.

Pumping Speed and Evacuation Time

Final vacuum level describes how low the mold pressure can become, but it does not reveal how quickly that pressure will be reached. Thermoforming machines, particularly thin-gauge packaging lines, often have very short forming cycles. The vacuum system must therefore combine sufficient pressure capability with adequate pumping speed.

For a simplified sealed volume and a pump with constant effective pumping speed, theoretical evacuation time can be estimated by:

Theoretical Evacuation Time

t  = 
V
Seff
×  ln
(
p1
p2
)
where:
  • t = theoretical evacuation time
  • V = total volume to be evacuated
  • Seff = effective pumping speed at the mold
  • p1 = initial absolute pressure
  • p2 = target absolute pressure

This relationship is useful for preliminary comparisons, but actual evacuation normally takes longer. Practical systems contain vacuum pipes, valves, filters, fittings and mold ports that restrict airflow. They may also experience leakage around sheet seals, forming-box joints and valve connections.

The total evacuated volume should include more than the visible mold cavity. Depending on the machine arrangement, it may include:

  • Mold passages and vacuum holes
  • The space below the heated sheet
  • Forming-box volume
  • Vacuum manifolds
  • Connecting pipelines
  • Valve chambers
  • Any additional process volume opened during the forming cycle

If these volumes are omitted, the selected vacuum equipment may appear adequate in calculation but respond too slowly during production.

Pumping speed must also be stated at a defined pressure. The inlet volume handled by a vacuum machine changes as gas pressure changes. Consequently, a catalogue capacity measured near atmospheric pressure cannot automatically be treated as the available flow throughout the complete evacuation cycle.

A useful approximation for converting gas volume between two conditions is:

Volumetric Flow Conversion

Q2  =  Q1  × 
p1
p2
 × 
T2
T1
where:
  • Q1 = volumetric flow at condition 1
  • Q2 = volumetric flow at condition 2
  • p1 and p2 = corresponding absolute pressures
  • T1 and T2 = corresponding absolute temperatures

This relationship assumes ideal-gas behaviour and consistent mass flow. In commercial equipment selection, the manufacturer’s verified performance curve should take priority over a simple conversion.

Cycle Time and Vacuum-System Response

Thermoforming vacuum demand is usually intermittent. A large quantity of air must be removed over a short forming period, followed by a recovery period during which the vacuum source prepares for the next cycle.

This creates two different capacity requirements:

  • Instantaneous capacity during mold evacuation
  • Average capacity over the complete production cycle

A vacuum receiver can provide the instantaneous capacity, while the blower or pump restores the receiver pressure during the interval between cycles. Without a receiver, the vacuum machine itself must respond directly to the full short-duration demand.

The following operating times should be established separately:

  • Time between opening the forming valve and initial sheet movement
  • Time required to draw the sheet against the main mold surfaces
  • Time required to reproduce corners, ribs and fine details
  • Vacuum holding time
  • Time available to restore the receiver vacuum
  • Total machine cycle time

A system can have an acceptable average capacity but still produce defective parts if its initial response is too slow. Conversely, a large receiver may create rapid initial sheet movement but fail to reach the required final pressure if the vacuum pump has insufficient recovery capacity.

Rapid evacuation is not always beneficial without limits. If vacuum is applied too aggressively, the softened sheet can make premature contact with the mold, producing uneven wall thickness, webbing or excessive local stretching. Vacuum application may therefore need to be coordinated with plug assistance, pre-stretching, sheet temperature and controlled valve timing.

The objective is not simply to obtain the highest possible flow. It is to establish the pressure profile required for consistent material distribution during each stage of the forming cycle.

Glossary

Absolute pressure: Pressure measured relative to a perfect vacuum. It provides a consistent reference for vacuum calculations across sites with different atmospheric pressures.
Conductance: The ability of a pipe or component to transmit gas under vacuum conditions. It depends on dimensions, geometry, gas and flow regime, and it affects the pumping speed available at the mold.
Evacuation time: The time allowed to reduce mold pressure from its initial value to the target value. It is affected by the evacuated volume, effective pumping speed, leakage and flow restrictions.
Mold volume: The internal volume evacuated during the forming step, including connected passages up to the defined isolation point. A larger volume generally requires more gas removal to reach the same target pressure in the same time.
Peak vacuum demand: The maximum transient gas-removal rate required during a forming cycle. It depends on the mold volume, pressure profile, valve timing and receiver contribution.
Pressure recovery profile: The change in receiver or header pressure over time after a forming event or isolation. It shows how quickly the vacuum source restores the required operating pressure.
Pressure-time curve: A record of vacuum pressure throughout a defined forming cycle. It can be used to compare evacuation, holding, venting and recovery stages against cycle requirements.
Pumping speed: The gas volume a pump removes per unit time at a stated inlet pressure and condition. The speed available at the mold can be lower because of losses in connecting pipes, valves and other components.