PCL Cyclone Air Lock for Filter and Cyclone Discharge

The PCL cyclone air lock is a rotary solids-discharge device for removing collected material from cyclone, filter and pneumatic-cyclone outlets. Installed below the collection cone or hopper, it transfers solids to downstream equipment while restricting unwanted air exchange through the discharge point. Its role differs from a blow-through air lock, which feeds material directly into a conveying-air stream.

A cyclone separates particles from a gas stream; the air lock handles the separated solids after they collect in the lower section. It does not perform the separation itself. The cyclone, hopper, air lock and downstream receiver must work together so collected material can leave the system without disrupting the gas-flow conditions required by the collector.

PCL Cyclone Air Lock for Filter and Cyclone Discharge, air lock, air-lock, Pasifik Air Lock, rotary valve, rotary feeder, pocket feeder, rotary air seal
Pasifik Cyclone Air Lock (PCL Model)
Type A B C D ØE F
PCL250 250 300 170 265 250 300
PCL280 284 390 214 320 280 410

* All dimensions are shown in mm.

How the Cyclone Discharge Air Lock Works

In a cyclone, the incoming gas-solid mixture follows a rotating path. Particles with sufficient inertia move toward the cyclone wall and descend into the conical collection area, while the gas continues toward the cyclone’s gas outlet. The material collected below must then be discharged without allowing uncontrolled air to enter or escape through the bottom opening.

The rotary mechanism moves material through pockets as the rotor turns. Solids enter from above, travel within the rotor assembly and discharge into the equipment below. This allows continuous or regularly controlled removal, depending on the feed conditions and selected operating arrangement.

The air lock also limits gas exchange at the solids outlet. It does not create a hermetic seal: gas can pass through operating clearances, and the amount depends on the valve design and system conditions. In an induced-draft installation, air entering through the outlet can affect the cyclone’s internal flow. In a pressurized system, leakage may move outward and create dust or product loss. The air lock must therefore be selected as part of the collector system, not treated as an independent dust-discharge accessory.

Terms such as rotary airlock valve, cyclone discharge valve, rotary valve, rotary feeder and rotary air seal may describe this equipment or its function. “Air seal” refers to limiting gas transfer; it does not mean zero leakage. The PCL configuration shown is intended for solids collection and discharge beneath a separator. Unlike a blow-through rotary valve, it is not described as routing conveying air through the rotor to entrain solids into a pipeline.

Open and Closed Configurations

The supplied product description identifies open and closed air-lock types. It specifies closed types for outlets of filters, dust cyclones and mono-cyclones, and open types only for pneumatic-cyclone outlets. It also states that both configurations use the same operating principle.

The drawing does not define the detailed constructional difference between the open and closed executions. It therefore does not support claims about differences in leakage, pressure capability, sealing performance or rotor geometry. The configuration should be matched to the separator outlet and downstream arrangement using the relevant assembly drawing.

A cyclone installation may discharge material to a bin, screw conveyor, rotary conveyor or another process stage. The transition below the cyclone should be designed to avoid material accumulation and prevent dust from escaping during normal operation. Where the system operates under vacuum or positive pressure, the designer should assess gas leakage through the air lock and its effect on collector performance.

Selection and System Integration

The required solids-discharge rate depends on the quantity and properties of the collected material, not only on the size of the air lock. Bulk density, particle-size distribution, moisture, cohesion and abrasiveness affect how material reaches and passes through the rotor. Fine dust may become airborne or compact; sticky material may adhere to internal surfaces; abrasive particles may wear the rotor and housing over time.

The cyclone hopper must deliver solids consistently to the air-lock inlet. A blockage or stagnant material zone can interrupt discharge even if the rotor continues turning. Likewise, a restricted outlet below the air lock can cause material to accumulate and interfere with the next rotor pockets. The equipment layout should provide appropriate access for inspection and cleaning.

The air lock’s effect on the gas system also requires review. Leakage at the bottom outlet can change air entering the collector, while leakage through the rotor clearances can affect material discharge and dust containment. Cyclone outlet plugging, erosion and air infiltration are recognized operating concerns in dust-collection systems; monitoring should therefore include both the solids path and the collector’s gas-side performance.

For a technical enquiry, provide the separator type, whether the required air lock is open or closed, the material’s properties, expected solids loading and discharge rate, operating pressure conditions, downstream equipment and installation dimensions. Also confirm the required construction materials, drive arrangement, maintenance access and any hazardous-dust protection or certification requirements. The supplied drawing does not specify pressure or temperature limits, leakage rates, drive ratings or material compatibility; these must be confirmed before final selection.