Air Locks

Pasifik industrial air locks transfer bulk solids between equipment while limiting unwanted gas exchange at the material discharge point. In bulk-solids systems, a rotary airlock valve can meter material from a hopper, feed solids into a pneumatic conveying line or discharge dust collected by a cyclone or filter.

The terms rotary valve, rotary feeder, pocket feeder and rotary air seal are also used for this equipment, although their exact meaning can vary by application. An air lock is not a gas-tight isolation valve: operating clearances allow some leakage, which must be considered when the connected system operates under positive pressure or vacuum.

The three air-lock configurations in this product range address different installation duties. PAL is the blow-through model, PRV is the regular gravity-discharge model, and PCL is designed for cyclone and filter discharge arrangements. Selecting the model starts with the point where solids enter and leave the valve and the equipment connected to each side.

Model Families and Available Types

Model Configuration and Primary Duty Available Types
PAL Blow-through air lock for feeding solids into a pneumatic conveying stream PAL200, PAL270, PAL350, PAL486, PAL640
PRV Regular rotary air lock for gravity discharge to downstream equipment PRV200, PRV270, PRV350, PRV486, PRV640
PCL Cyclone and filter discharge air lock, available in open and closed executions PCL250, PCL280

The listed model codes identify product types; the correct selection still depends on material behaviour, required feed rate, installation arrangement and system pressure conditions. Dimensional drawings and the corresponding model data should be reviewed before specifying a unit.

PAL Blow-Through Air Lock

The PAL model is intended for applications where bulk solids must enter a pneumatic conveying stream through a blow-through rotary valve. Material falls into the rotor pockets from above and moves toward the discharge, where conveying air carries it into the line. The valve and the conveying-air connection therefore form part of the same feed interface.

This arrangement differs from a regular gravity-discharge air lock. It is used when the process calls for solids to be introduced directly into the conveying route, rather than simply dropped into a receiver or process vessel below the valve. The line entry, conveying-air arrangement, rotor discharge and material feed should be assessed together. The supplied drawing does not define a performance curve, conveying capacity or allowable pressure range, so these values must be confirmed for the specified application.

PRV Regular Air Lock

The PRV model is the regular, gravity-discharge configuration. Solids enter through the upper inlet, are carried in rotating pockets and fall from the lower outlet into receiving equipment. Applications may include controlled discharge from hoppers, bins and compatible process equipment.

The PRV is distinct from the PAL blow-through model in its described discharge arrangement. It is not specified as routing conveying air through the rotor to entrain material into a pipeline. It can be installed above downstream equipment, but the receiver and outlet connection must accommodate the discharged solids without causing accumulation.

A rotary feeder cannot correct poor material flow from the vessel above it. Bridging, compaction or an obstructed outlet can prevent consistent pocket filling even when the rotor continues to turn. The hopper outlet and air-lock inlet should therefore be reviewed together.

PCL Cyclone and Filter Discharge Air Lock

The PCL model is intended for solids collected at separator outlets. In a cyclone or filter system, particles accumulate in a hopper or cone and must be discharged while limiting unwanted air exchange through the lower outlet. The air lock handles the collected solids; it does not carry out the gas-solid separation performed by the cyclone or filter.

The supplied product description identifies two executions. Closed-type air locks are specified for filter, dust-cyclone and mono-cyclone outlets. Open-type air locks are specified only for pneumatic-cyclone outlets. The description states that both types use the same operating principle, but does not define their constructional differences. Those differences, and any related pressure or leakage limits, should be confirmed from the relevant assembly drawing and product specification.

The PCL application is therefore defined by the separator outlet and the downstream solids-handling arrangement. Its installation should account for the material collected, the collector’s operating pressure, the risk of air entering or escaping through the discharge point and the way solids are removed below the valve.

Selection and System Integration

An air lock should be selected for the complete process duty, not by model code alone. Material characteristics affect how solids enter, occupy and leave the rotor pockets. Particle size, bulk density, moisture, cohesion, abrasiveness and temperature can influence feed consistency, wear and the risk of deposits. The required mass feed rate and operating schedule are also needed to determine whether a selected size and rotor speed can serve the process.

Pressure conditions matter because leakage through a rotary airlock can affect both solids feed and system performance. In a positive-pressure conveying line, air may leak toward the material inlet; in a vacuum system, air may enter from the surroundings. The amount and effect depend on the equipment and installation. The air lock should not be treated as certified explosion isolation or as a substitute for a pressure-rated shut-off device unless the specific assembly has been assessed and approved for that safety function.

For a technical review, provide the material data, required feed rate, pressure conditions on both sides, upstream hopper geometry, downstream connection, operating sequence and available installation space. For PAL, include the pneumatic conveying line and air-entry arrangement. For PCL, identify the separator type and whether the required execution is open or closed. The supplier should confirm the proposed construction, drive, clearances and operating limits against the intended service.