Industrial Roots Blowers

Pasifik Roots Blowers from are positive-displacement machines for defined industrial air and gas duties in pressure or vacuum service. Model selection depends on the required flow, differential pressure, inlet conditions, connected equipment and operating cycle.

The product range includes two-lobe and three-lobe configurations. Each model has its own performance limits, so selection should be based on the specified operating point rather than a general application label, connection size or motor rating.

Roots blowers are used in processes such as wastewater aeration, pneumatic conveying, paper and pulp production, flotation and selected surface-treatment duties. These applications impose different requirements for pressure, airflow, contamination control and operating range. A model suitable for one duty should not be assumed to suit another without a technical review.

Operating Principle and Product Configurations

A Roots blower traps and transfers gas between its inlet and discharge as its rotors turn. At a given speed, it moves a near-defined volume per revolution. The connected system establishes the operating pressure, while actual delivered flow, power and discharge temperature depend on speed, gas conditions, differential pressure and internal leakage.

In a two-lobe rotor configuration, each rotor has two lobes. In a three-lobe rotor configuration, each rotor has three. Lobe count alone does not determine application suitability; the relevant model data and required operating point govern selection.

Pasifik Roots Blower range covers nominal flow capacities from 30 to 9.392 m³/h and differential pressures up to 1,000 mbar, depending on the selected model, speed and operating conditions. Blowers can be supplied as bare-shaft machines, baseplate-mounted units or complete packages with acoustic enclosures.

Product Range at a Glance

Pressure and Vacuum Duties

For a positive-pressure duty, the blower supplies air or compatible gas to downstream equipment. The required differential pressure comes from the resistance of the complete system, including pipes, valves, filters, diffusers, feeders and process equipment. If a discharge path becomes restricted, pressure, absorbed power and discharge temperature can rise. Pressure protection is therefore required, and a relief device should not be used for routine airflow control.

Vacuum-exhauster service has a different system arrangement. The required suction pressure, inlet flow, pressure ratio, discharge condition and moisture or solids load need to be reviewed for the selected model. A vacuum-exhauster duty does not imply that a vacuum-booster package is available or included; any booster arrangement requires separate confirmation.

Applications involving process gases, corrosive or hazardous media, condensable vapour, liquid carryover or fine solids need a specific compatibility review. Provide gas composition, temperature, moisture and contamination data so the machine, seals and package can be assessed for the actual service. A standard air-duty performance curve does not establish suitability for these conditions.

Selection and Package Engineering

A technical enquiry should describe the complete operating case. For variable processes, provide minimum, normal and peak conditions, along with startup, shutdown and changeover cases where they affect the duty. Flow values should include their reference pressure and temperature; actual inlet flow, free-air flow and standard volume are not directly interchangeable.

Include the following information in the enquiry:

  • Required flow, inlet conditions and differential pressure or vacuum
  • Operating schedule, expected load range and simultaneous users
  • Gas composition or material properties, including moisture, dust, fibres or abrasive particles
  • Pressure losses through the connected pipework, valves, filters and process equipment
  • Site altitude, ambient conditions, electrical supply and noise requirements
  • Required control method, package arrangement, instruments and standby capacity

The package specification should define what the offer includes: blower, motor and drive, base, guards, enclosure, accessories, controls, documentation and services. It should also identify the interface with plant piping and electrical systems. Clear scope boundaries help procurement compare equivalent offers and reduce missing items during installation.

Variable-speed drives, staged operation and branch control can be used where they suit the process and remain within the blower and motor’s approved limits. Reduced speed can affect motor cooling and blower temperature, so the permitted control range should be confirmed for the selected configuration. The relief valve protects against abnormal pressure; it is not a substitute for demand control.

Performance Review and Acceptance

The quotation should state the selected model, operating speed, flow at the defined reference condition, differential pressure, absorbed power, motor rating and expected discharge temperature. It should identify the applicable model limits and distinguish guaranteed values from calculated or typical data.

Factory performance data verifies the machine under stated conditions. Installed performance also depends on the customer’s piping, filters, valves, separators, controls and process operation. Agree in advance on measurement points, instruments, operating state and acceptance criteria.

At commissioning, record flow, pressure or vacuum, speed, motor load and temperature under representative process conditions. Where relevant, record the process result as well—for example, material delivery, water removal or aeration response. This provides a reference for later troubleshooting and helps separate machine performance from system or process changes.