Pasifik PCC Centrifugal Compressors supply process air by accelerating gas through a rotating impeller and converting part of that velocity into pressure. The three models—PCC460, PCC600 and PCC700—cover different airflow capacities and package sizes. Selection depends on the required flow at the operating pressure or vacuum, the process schedule and the resistance of the connected system.
These machines are used in applications where a compact, directly coupled air source can meet the required duty. Typical sectors include food processing, pneumatic conveying, chemical processing, printing, textile manufacturing, metalworking and refuse handling. The application name alone does not establish suitability: the air quality, operating point, materials and installation conditions must all match the process.
Matching the PCC model to the process load
The PCC460 and PCC700 have listed airflow ranges up to 10 m³/min. The PCC600 has a listed range up to 15 m³/min. Motor power and machine mass also vary between models, so the largest airflow figure should not be treated as a complete basis for choosing a unit.



| Model | Air Volume (m³/min) | Pressure ΔP (+) | Vacuum ΔP (-) | Electric Motor (kW) | Weight (kg) |
|---|---|---|---|---|---|
| PCC460 | 0 – 10 | 460 | 260 | 4 – 7.5 | 115 |
| PCC600 | 0 – 15 | 600 | 400 | 7.5 – 11 | 155 |
| PCC700 | 0 – 10 | 700 | 400 | 7.5 – 15 | 340 |
The motor ranges show the available rating range associated with each model; they do not identify the motor needed for every installation. The selected motor must meet the actual load at the specified operating point, with the correct supply voltage, frequency and starting method. A motor near the top of a range is not automatically suitable if the process operates at a different flow or pressure.
| Model | A | B | C | ØD | E | F | G | H | L | M | N |
|---|---|---|---|---|---|---|---|---|---|---|---|
| PCC460 | 270 | 455 | – | 83 | 500 | – | 135 | 625 | 1110 | 320 | – |
| PCC600 | 270 | 490 | – | 108 | 545 | – | 135 | 695 | 1130 | 320 | – |
| PCC700 | – | – | 870 | 80 | 745 | 1300 | 380 | 920 | 1600 | – | 260 |
* All dimensions are in mm.
Flow data also need a stated reference condition. Temperature, atmospheric pressure and altitude affect air density, which changes the mass of air delivered for a given volume. When comparing a required process flow with a machine rating, both values should use compatible reference conditions. This is especially relevant when equipment is installed at high altitude or draws air from a warm enclosure.
How the impeller develops pressure
Air enters the compressor near the centre of the impeller. As the impeller rotates, its blades accelerate the gas outward. The housing collects the moving air and guides it toward the outlet, where some of its velocity is converted into static pressure. This is dynamic compression that is the machine adds energy to a continuous gas stream.
The airflow delivered by a centrifugal machine changes with rotational speed, inlet-air density and discharge resistance. A model’s maximum flow value therefore does not show how much air it will deliver at every pressure. The selected operating point must be checked against the model’s performance data, including motor input at the required flow and pressure.
This operating behaviour differs from that of a positive-displacement machine, which moves a defined volume of gas during each revolution. With a centrifugal compressor, increasing system resistance generally changes the delivered flow. That makes the shape of the performance curve central to selection, particularly when the process demand varies during a shift or when several users share one air source.
Pressure and vacuum operation also require separate checks. The inlet and outlet connections, expected pressure differential and control method must be confirmed for the specified model. A compressor should not be assigned to vacuum service solely because a general product description mentions vacuum operation; the duty must fall within the approved range for that configuration.
The PCC design uses an impeller, housing and motor in a directly coupled arrangement. The impeller and housing are made from high-strength aluminium alloy; cast iron housing construction is used in some cases. A direct-coupled drive removes belt transmission from the package, while the final arrangement still needs adequate access for inspection, lifting and motor service.
Where the PCC range fits process work
In pneumatic conveying, the compressor supplies the conveying air that carries dry bulk solids through a pipeline. The feeder, pipeline diameter, route length, bends, elevation changes and receiving filter all affect the airflow and pressure required. A compressor should be selected from the complete system duty; using the solids name or conveying capacity alone is insufficient.
Food-processing installations may use compressor air for conveying, aeration or other process functions. Where air contacts ingredients or product-contact surfaces, the buyer should specify required limits for oil, particles, moisture and microbiological contamination. A lubrication-free machine description does not establish a defined air-purity class or confirm that the complete package meets food-contact requirements.
Chemical-processing duties call for a review of the gas composition and the materials exposed to it. The aluminium alloy and any cast-iron housing option should be checked against humidity, condensate, cleaning agents and potential chemical carryover. If the process moves a gas other than ambient air, the gas density and compatibility must be evaluated for the actual composition and temperature.
Printing, textile and metalworking plants may use compressed air for process support, product handling or conveying. In each case, demand can change with production state. A machine that operates continuously at one point may not suit a line that frequently starts, stops or changes airflow. Controls should match the compressor’s permitted operating range and the process’s real demand pattern.
Refuse-handling systems can involve dust and variable material conditions. The air inlet and upstream filtration should be positioned to limit dust entry, while the discharge side should be protected from reverse flow and process contamination. Filter pressure loss belongs in the system calculation because a loaded filter can change compressor inlet conditions and reduce useful air delivery.
Installation details that affect performance
The compressor should be installed with enough free space for cooling air to reach the motor and housing. Enclosures and nearby equipment must not block ventilation openings. If the machine is placed indoors, the room should remove the heat released by the motor and compressor during operation.
The inlet should draw from a clean location away from dust sources, hot exhaust, chemical vapour and water spray. Inlet filtration should suit the environment and the compressor’s allowable restriction. A filter that is too small can add unnecessary pressure loss; a damaged or poorly seated element can allow contamination into the machine.
Discharge piping must be sized for the required flow and supported independently. Misalignment or excessive pipe load can stress the compressor connections. The layout should also include the isolation devices, instrumentation and protective equipment required by the approved package design. Pressure-relief protection must be selected and installed for the actual system; it should not be used as routine flow control.
Noise should be assessed at the installation, even when the machine is described as low-noise. The motor, inlet, outlet, foundations and connected piping all contribute to sound and vibration. If the site has a sound limit, request model-specific sound data and assess the installed package under representative operating conditions. An enclosure may help, provided that its ventilation prevents excess temperature.
The mass difference between models affects handling and foundation design. The PCC460 is listed at 115 kg, the PCC600 at 155 kg and the PCC700 at 340 kg. Lifting points, floor capacity, anchor layout and access for maintenance should therefore be checked against the selected model’s approved drawing, not estimated from the smallest package.
Information to confirm before ordering
A reliable selection starts with the process requirement: pressure or vacuum service, required flow and its reference condition, expected hours of operation, and the number of users that may run simultaneously. The system calculation should include pipeline losses, filters, silencers, valves and downstream equipment.
The machine’s pressure and vacuum figures must be stated with units and linked to the relevant performance curve. Motor input, inlet conditions and permitted operating range should be confirmed at the selected point. If demand varies, the control strategy should be reviewed with the compressor data so the machine can follow normal process changes without operating outside its approved limits.
The supplied dimensional drawing should be checked against the site layout, connection orientation, service clearance and lifting path. Material selection also needs confirmation for the actual gas and environment. These checks allow procurement, engineering and maintenance teams to evaluate the same defined configuration before the equipment is released for manufacture.